1. What the sizing result means
Published by Coreless DC MotorPublished Reviewed
This guide supports preliminary selection for a low noise brushless DC motor. It includes no measured product acoustic dataset, stock SKU, price or performance approval.
1.223 W
Shaft demand, not a motor rating
146 RPM at 80 mNm requires 1.223 W mechanically. It does not establish continuous motor capability.
Calculation / selection method30:1
One illustrative reduction
A loaded motor speed of 4,380 RPM divided by 146 RPM gives 30:1. Other windings and ratios can meet the target.
Calculation / selection methodFOC candidate
Compare control methods
TI compares audible noise qualitatively. Confirm the improvement on the selected motor and load.
Source: TI, Table 2-2Separate mechanisms
Cogging differs from commutation ripple
Changing commutation does not by itself remove design-dependent cogging.
Source: maxonNoise unknown
Measure before acceptance
An ISO sound-power method requires more than a single distance reading. Request an agreed test protocol and uncertainty.
Source: iso37442. 12V low noise DC motor 146rpm brushless: define the loaded target
Start with the load. A 12 V supply and 146 RPM label do not establish shaft torque, speed regulation, acoustic performance or suitability for a pump. Ask whether 146 RPM is a no-load rating or a loaded requirement, and specify the tolerance and continuous torque.
| Candidate | What it offers | What must be verified |
|---|---|---|
| Slotless BLDC + reduction | Choose a motor operating point and ratio to meet loaded output speed. | Gear torque, mesh tones, backlash, efficiency, life and envelope. |
| Outer-rotor direct drive | Eliminates the gear transmission; may change available space and feedback requirements. | Loaded starting torque, continuous heating, low-speed control and total assembly noise. |
| Brushed gearmotor alternative | Consider when simple control and initial cost dominate. | Brush wear, service duty, gearbox behavior and measured cost comparison. No life value is assumed. |
Choose the geared candidate when packaging and torque multiplication justify transmission complexity. Consider direct drive when backlash and mesh tones dominate, then obtain a torque-speed and thermal assessment. These are selection paths, not product recommendations.
3. Reproduce the calculation and check its limits
Use speed and torque at the same loaded output shaft. The example assumes 80 mNm, 146 RPM, 12 V, 4,380 loaded motor RPM and 64% total DC-to-output efficiency. The efficiency is illustrative and editable.
| Output | Calculation | Interpretation |
|---|---|---|
| Shaft power | 2π × 146 × 0.080 / 60 = 1.223 W | Mechanical demand; does not prove continuous capability. |
| Required ratio | 4,380 / 146 = 30:1 | Kinematic requirement; availability and gear strength remain unknown. |
| DC supply current | 1.223 / (12 × 0.64) ≈ 0.159 A | Steady estimate; excludes startup, stall and protection sizing. |
| Absolute noise | Unknown — no measured baseline | No pass/fail noise category or guaranteed reduction. |

The tool accepts 3–48 V, 10–25,000 output RPM, 1–5,000 mNm and 1–100% assumed efficiency. Loaded motor speed for a reducer must be greater than output speed and no more than 100,000 RPM. These are calculation limits. Even an accepted input may describe an impossible motor, winding or gearbox.
The result excludes acceleration and inertia, friction peaks, shaft loads, winding resistance, current limits, thermal time constants, duty cycle, controller overhead and gearbox losses beyond the efficiency assumption. Supplier curves and loaded tests determine whether a candidate works.
4. Find the noise path before changing hardware
Compare one variable at a time using the same speed, torque and mount. Record the motor alone, the coupled load and the final enclosure. A change in the dominant tone after coupling helps identify where further investigation belongs.
| Suspected path | Comparison | Next step |
|---|---|---|
| Drive / commutation | Same motor and load with controlled current waveform changes. | Tune the current loop and record electrical and acoustic behavior together. |
| Bearings / alignment | Motor uncoupled versus coupled with checked alignment. | Check shaft load and bearing specification; avoid adding preload without review. |
| Gear mesh | Same output condition across candidate transmissions. | Request loaded noise, backlash and lubricant-temperature data. |
| Mount / enclosure | Same assembly on fixture versus installed chassis. | Trial isolation or structural changes, then verify alignment and heat flow. |
5. Choose control and motor architecture together
TI’s comparison favors sinusoidal and FOC control for audible noise relative to trapezoidal control, with tradeoffs in switching losses and algorithm complexity. It does not establish a fixed dB reduction for a particular motor. Match the control method to the motor and the application.
Source: TI, Table 2-2maxon distinguishes commutation ripple from cogging. Ordinary FOC does not by itself eliminate cogging in an iron-core motor. Check winding inductance, current ripple, feedback and tuning; a PWM frequency alone cannot certify silence.
Source: maxonFor 146 RPM direct drive, include loaded startup and very slow motion in the controller trial. If speed estimation is unreliable, evaluate suitable feedback with the supplier. For a geared drive, assess both motor speed and output regulation rather than treating 12 V as a speed setting.
6. Compare acoustic evidence on the same basis
| Reference | Published scope | Boundary for this page |
|---|---|---|
| ISO 3744:2025 | Engineering sound power from sound pressure in an essentially free field over a reflecting plane. | Not a universal 30 cm medical-motor limit. |
| ISO 3745:2012 | Precision sound-power / sound-energy methods for anechoic and hemi-anechoic rooms. | A single microphone reading is not a complete sound-power determination. |
| IEC 60034-9:2021 | Noise limits with published rated-output scope beginning at 1 kW. | Do not use these limits to approve the 1.223 W miniature drive example. |
Agree LpA at a stated location or LWA from a defined method before comparing suppliers. Record loaded speed and torque, supply, controller settings, fixture and orientation, microphone geometry, weighting and averaging, background, instrument calibration and uncertainty. Ask the laboratory to select the applicable method and document deviations.
No fixed background floor, mounting material or microphone distance is imposed here. Report those conditions explicitly. A supplier’s free-running motor test cannot establish the noise of your mounted pump or actuator.
7. Optional distance comparison: a conditional estimate
When a measured 30 cm baseline exists for the same assembly, the tool can apply LpA(r) = LpA(30 cm) − 20 log10(r / 30 cm). This ideal spherical-spreading relationship assumes a point-like source in the free-field far field, with the same direction and operating state and negligible background.
For an illustrative input of 40 dB(A) at 30 cm, the ideal value at 100 cm is 29.54 dB(A). This is a worked calculation, not a measurement. Near-field behavior, reflections, extended sources and background invalidate the approximation. Remeasure at the acceptance location.
8. Three decisions to test before ordering
Compact metering drive
Premise: Assume 12 V, 146 RPM and 80 mNm continuous output.
Process: Calculate 1.223 W and request a loaded motor point and gear rating. Trial the pump under its real pressure and tubing conditions.
Decision: Proceed to sample testing only after torque, heating, flow and noise are documented.
Backlash-sensitive camera axis
Premise: Assume the same output target with tight reversal accuracy.
Process: Compare direct drive with a geared candidate; include inertia, feedback resolution, holding current and thermal duty.
Decision: Choose using measured reversal error and mounted noise; the missing gearbox alone does not prove suitability.
Instrument with a customer noise limit
Premise: Assume the assembly must meet an agreed LpA limit at 1 m.
Process: Leave baseline blank until a sample is measured. Agree background and uncertainty; record the actual mounted load.
Decision: Use the measured test result for acceptance. A distance translation is only a planning check.
| Risk | Consequence / cost | Mitigation / alternative |
|---|---|---|
| No-load speed used as loaded speed | Wrong ratio or inadequate torque; sample redesign. | Obtain loaded curves and startup data before freezing the ratio. |
| Direct drive selected only for silence | Feedback, winding, thermal or packaging changes may dominate cost. | Compare installed cost and samples against a geared solution. |
| Polymer gears assumed automatically quiet | Load, temperature, lubricant and wear can change behavior. | Request rated life and loaded acoustic tests; compare metal gear alternatives. |
| Isolation added without integration checks | Alignment, positional stiffness and heat removal may deteriorate. | Test mount changes under the real load and thermal duty. |
| Architecture treated as a life or noise guarantee | False acceptance and rework. | Agree measurable acceptance criteria and sample testing; no lifetime is inferred here. |
9. Sources, evidence status and purchasing checklist
Source review date: 2026-11-14. Sources below support mechanisms and published test scopes. Public evidence reviewed here does not establish a specific 12 V / 146 RPM product’s dB(A), lifetime, dimensions, price or continuous torque rating. Confirm edition status and the full method with your test laboratory.
- TI — Brushless-DC Motor Driver Considerations and Selection Guide, Rev. A (2022), Table 2-2
Qualitative control-method tradeoffs; no universal dB(A) saving.
- maxon — PWM current ripple, torque ripple and cogging ripple (2026)
Distinguishes current ripple, commutation ripple and design-dependent cogging.
- ISO 3744:2025 — engineering sound-power measurement
Sound power from sound-pressure measurements over an enclosing surface in an essentially free field over a reflecting plane.
- ISO 3745:2012 — precision sound-power measurement
Anechoic / hemi-anechoic room methods; not a universal motor noise limit.
- IEC 60034-9:2021 — rotating-machine noise limits
Published scope includes rated output from 1 kW; do not apply its limits to this 1.223 W example.
The formulas, examples, investigation plan and application tradeoffs are this page’s engineering guidance. The default values are disclosed assumptions. No supplier SKU has been qualified, and no lab or regulatory compliance is claimed.
Before ordering, send the exported RFQ together with duty cycle, environment, available space, shaft loads, driver and feedback constraints, loaded speed tolerance, peak torque, and the proposed acoustic acceptance protocol. Request a sample, curves, test report and a quotation covering motor, gearbox, controller, feedback, fixtures and any engineering charges.
10. Questions for selection, acoustics and testing
12V 146 RPM selection
Is 146 RPM an industry-standard optimum for a 12V brushless motor?
No universal optimum is established by the sources reviewed here. Treat 146 RPM as your loaded output requirement. Pump flow depends on displacement, tubing, compression and load; verify it on the actual pump.
Calculation / selection methodWhat does 12V low noise DC motor 146rpm brushless specify?
It specifies a supply, an output-speed target and a preferred commutation architecture. It does not specify torque, duty, speed tolerance, envelope, feedback or a measurable noise acceptance limit. Add those before requesting a quotation.
Calculation / selection methodHow much shaft power does 146 RPM at 80 mNm require?
P = 2πnT/60 with torque in N·m gives 1.223 W. At an assumed 64% total DC-to-output efficiency and 12 V, supply current is about 0.159 A. Startup and stall need separate measurements.
Calculation / selection methodDoes a 30:1 gearbox guarantee 146 RPM?
Only when loaded motor speed is 4,380 RPM. Supply voltage alone does not fix speed under changing load. Confirm the loaded torque-speed curve, controller speed regulation and gearbox continuous rating.
Calculation / selection methodCan I use direct drive at 146 RPM?
It is a candidate if the motor supplies the required continuous torque and starts the actual load without gearing. Check cooling and feedback at low speed. Removing a gearbox removes its mesh noise and backlash, but does not make the complete drive silent.
Calculation / selection methodControl and acoustics
How many decibels does FOC save?
There is no universal number. TI rates sinusoidal and FOC control favorably for audible noise relative to trapezoidal control, while also describing switching-loss and complexity tradeoffs. Compare matched samples under the same conditions.
Source: TI, Table 2-2Does FOC eliminate cogging?
No. maxon distinguishes design-dependent cogging from commutation ripple. A controller may need a specific compensation algorithm; ordinary sinusoidal commutation alone is not such compensation.
Source: maxonIs a PWM carrier above 25 kHz a guarantee of silence?
No. Current ripple, feedback, winding inductance and mechanical excitation still matter. Choose switching frequency within motor and driver limits, check losses and temperature, and then measure the assembly.
Source: maxonCan lowering voltage be assumed to lower noise?
No fixed improvement is assumed. Closed-loop drives may maintain speed while changing duty cycle; an open-loop drive may lose speed or fail to start. Recheck torque, current, temperature and noise at the actual operating point.
Calculation / selection methodTesting and purchasing
Can this tool predict absolute motor noise without a measurement?
No. It has no calibrated acoustic dataset. Leave the optional baseline blank to retain an unknown noise result and request a loaded assembly measurement. A topology label cannot replace an acoustic test.
Calculation / selection methodCan I convert a 30 cm sound-pressure reading to 1 m?
Only as an ideal approximation for a point-like source in the free-field far field along the same direction. The change is −20 log10(100/30) = −10.46 dB. Room reflections, near-field effects and background can invalidate the estimate; remeasure for acceptance.
Calculation / selection methodIs ISO 3744 a 30 cm medical-motor noise limit?
No. ISO 3744 defines an engineering method for determining sound power from sound-pressure measurements in an essentially free field over a reflecting plane. It does not establish a universal 30 cm bedside limit.
Source: iso3744How do sound pressure and sound power differ?
LpA describes pressure at a measurement location. LWA describes sound power inferred using a defined measurement method. A single LpA reading cannot be compared directly with an LWA declaration.
Source: iso3745Can IEC 60034-9 limits certify this miniature motor?
The cited 2021 edition describes machines with rated output beginning at 1 kW, so its limits do not establish acceptance for the illustrative 1.223 W drive. Agree a suitable measurement method and application-specific acceptance limit.
Source: iecWhat should I send with an RFQ?
Send voltage, loaded speed and tolerance, continuous and peak torque, startup load, duty, ambient and cooling, available space, shaft loads, feedback and driver requirements. Add an agreed LpA or LWA limit with load, mounting, direction, distance, background and uncertainty.
Calculation / selection method