Driving Low-Inductance Coreless Motors: High-Frequency PWM, GaN Drivers, and Series Filter Chokes Sourcing Guide (2026)
2026/10/28

Driving Low-Inductance Coreless Motors: High-Frequency PWM, GaN Drivers, and Series Filter Chokes Sourcing Guide (2026)

Compare low-inductance coreless motor PWM drives, GaN stages and series chokes. Use ripple calculations and an RFQ checklist to plan motor-drive qualification.

Sourcing decision baseline: Qualify a low-inductance coreless motor together with its PWM drive. Specify the bus voltage, modulation scheme, effective winding inductance, operating current and allowable heating before choosing a switching frequency or series choke. A 20 kHz controller may need mitigation; a 100 kHz GaN stage may still need a choke. Neither frequency nor semiconductor material alone establishes compatibility.

Published and sources reviewed: 28 October 2026. Scope: Global OEM procurement of miniature brushed coreless and slotless brushless DC motor systems. The calculations below model a brushed motor circuit; brushless systems require their actual phase parameters and modulation model. These are engineering screening examples, not measured product performance, supplier quotations or medical-device qualification evidence.

Preparing a motor-and-drive enquiry? Start with the coreless DC motor RFQ checklist, then add the PWM acceptance requirements below.

Why a Coreless Motor Can Overheat on a PWM Drive

A motor that runs normally on a DC bench supply can run hotter on a PWM controller at the same speed and load. Switching adds current ripple, increasing RMS current and winding losses. This is one possible explanation for no-load heating; friction, incorrect brushless commutation, current-loop instability and excessive speed also need checking.

Compare DC and PWM operation at matched shaft conditions, mounting and ambient temperature. Record winding or case temperature using an agreed method and stop limits. Case temperature alone does not establish winding temperature or identify the failure mechanism. No universal time-to-failure or temperature rise follows from the PWM frequency.

Miniature brushless motor pair beside a driver board; product illustration rather than a tested motor-drive pairing

Physics of Low Inductance: Ironless Windings vs. Iron-Core Actuators

A brushed coreless motor has a self-supporting rotating winding without iron teeth. A slotless brushless design has stationary windings and an electronically commutated rotor. Both can have low winding inductance, but diameter alone does not predict inductance, resistance or permissible ripple.

The electrical time constant is tau_e = L / R, with inductance in henries and resistance in ohms. A short time constant allows current to change substantially within a PWM period. Request the actual winding data and measurement conditions rather than inferring electrical behavior from frame size.

maxon's current-ripple guidance distinguishes modulation schemes and notes that effective inductance under PWM can be lower than a 1 kHz catalogue measurement. Its 30–80% range is manufacturer guidance, not a universal correction for every motor. Use supplier-supported effective inductance at the intended frequency and current.

Current-Ripple and Thermal-Loss Calculations: State the PWM Model First

1. Peak-to-Peak Current Ripple

For an ideal winding circuit, L_total * di/dt = v_terminal - E - i * R_loop, where E is back EMF and R_loop includes winding and series resistance.

For 0/V_bus terminal PWM, continuous current and small current excursion per cycle, treating resistance drop and back EMF as constant gives:

Delta_I_pp ≈ V_bus * D * (1 - D) / (L_total * f_pwm)
At D = 0.5: Delta_I_pp ≈ V_bus / (4 * L_total * f_pwm)

Here f_pwm is the repetition frequency of that terminal-voltage waveform. This is consistent with the applicable 1-quadrant / 3-level-controller formula in maxon's guidance. Do not apply the factor of four to every H-bridge or three-phase inverter. For ideal bipolar switching between +V_bus and -V_bus, the corresponding maximum is V_bus / (2 * L_total * f_pwm) at 50% duty. Verify how the controller defines PWM frequency and modulation.

For a brushed two-wire circuit, L_total is effective motor inductance plus all series inductance in the current loop. One choke contributes its value; two equal chokes contribute twice that value. A common-mode choke's nameplate inductance is not automatically usable differential-mode inductance. For brushless FOC or six-step operation, use the manufacturer's phase/line convention and switching states rather than copying the brushed formula.

2. RMS Current and Winding Heating

For approximately triangular ripple, I_rms² ≈ I_avg² + Delta_I_pp² / 12, and added winding copper loss is P_ripple ≈ R_motor * Delta_I_pp² / 12. Average current determines average electromagnetic torque in the brushed model; shaft torque also includes mechanical losses. Brushless torque requires the appropriate phase or q-axis current convention.

If the PWM period is not short relative to L_total / R_loop, current is exponential rather than triangular. For an ideal, steady, bidirectional-current 0/V_bus waveform at 50% duty, constant E, L and R, the exact RL result is:

x = R_loop / (4 * L_total * f_pwm)
Delta_I_pp = (V_bus / R_loop) * tanh(x)
P_ripple = R_motor * (V_bus / (2 * R_loop))² * (1 - tanh(x) / x)

These expressions follow from solving the RL equation over each half-cycle and averaging the squared ripple. They exclude dead time, diode drops, discontinuous-current clamping, magnetic losses and frequency-dependent parameters. They estimate winding ripple copper loss, not total motor heating or temperature rise. A diode-only freewheel stage that prevents current reversal needs a different model.

3. Worked Example: Why a Frequency Label Is Insufficient

Use hypothetical inputs V_bus = 24 V, R_motor = 4 ohms, effective L_motor = 30 µH and I_cont = 0.8 A. Assume the 50% duty RL model above, negligible other resistance and unchanged effective motor inductance between cases.

  • Case A — 20 kHz, no choke: The triangular approximation gives 10.0 A peak-to-peak and 33.3 W ripple copper loss. Here L/R = 7.5 µs, versus a 50 µs PWM period, so that approximation is poor. The exact RL model instead gives 5.59 A peak-to-peak and 15.89 W. These are modeled values, not measurements or a predicted burnout time.
  • Case B — 100 kHz, two 40 µH series chokes: L_total = 110 µH. The exact model gives 0.544 A peak-to-peak and 0.099 W of winding ripple copper loss. Choke losses and driver losses remain additional.

Even Case B has ripple around 68% of the illustrative 0.8 A continuous rating. It does not meet a hypothetical 15% procurement target. The I_cont² * R = 2.56 W copper-loss reference also leaves no extra copper-loss allowance at full rated average current under unchanged cooling. Qualification must account for load current, ripple, other losses and the supplier's thermal conditions together.

Architectural Visual: Current Ripple and Mitigation

The diagram uses the worked example above. Waveforms are schematic; the numbers come from the ideal RL calculation, not an oscilloscope capture. Enlarge the image to read the details.

Calculated PWM ripple comparison: 24 V brushed coreless motor at 20 kHz without chokes versus 100 kHz with two 40 microhenry series chokes; schematic waveforms, not test data

Failure Modes to Investigate During Motor-Drive Qualification

Brush and Commutator Wear

Current peaks and commutation transients can affect contact wear in brushed motors. Obtain the motor supplier's brush-system restrictions and validate service life under the intended drive, load and duty cycle. Precious-metal versus graphite selection cannot be approved from a generic ripple percentage. A smoother supply does not eliminate mechanical brush wear or commutation arcing.

Additional Heating and Magnetic Losses

RMS current raises copper losses. PWM-related magnetic losses can also occur in conductive motor structures and are outside the simple RL calculation. Check the actual winding, magnet and adhesive temperature limits. Do not infer demagnetization, insulation failure or a lifetime reduction from the ripple estimate alone.

Acoustic Noise and Control Stability

Raising the carrier above the audible range can reduce carrier-related whine, but commutation, subharmonics, mechanical vibration and control behavior can remain audible. Added inductance changes current-loop dynamics; verify controller stability and high-speed operation after installing filters.

Six-Path Architectural Sourcing Matrix

These are qualification choices, not guaranteed temperature, lifetime or price outcomes. Obtain comparable quotations at the same annual volume, ratings, qualification scope and delivery terms. Count engineering work, NRE, assembly, cooling and enclosure space alongside component cost.

ArchitectureWhen to Consider ItRipple / Thermal Trade-offSpace and Cost Items to QuoteAcceptance Evidence
Existing silicon PWM stageReuse of a 16–25 kHz controllerMay be viable with adequate effective inductance, bus voltage and load margin; no blanket prohibitionBaseline controller plus any required mitigationActual modulation, internal chokes, current traces and thermal limits
External series chokesRetrofitting a controller with excessive rippleMore loop inductance reduces ripple; DCR, core losses and slower current response are trade-offsOne or two brushed-circuit chokes as designed, or the specified brushless filter; mounting and coolingInductance versus bias/temperature, saturation curve, RMS heating and loop retuning
High-frequency GaN stageCompact designs where switching losses limit higher PWM frequencyCan enable higher frequency; does not itself guarantee low ripple or remove chokesPower stage, sensing, gate-drive supply, PCB layout, EMI work and firmwareEfficiency map, ringing, temperature and current traces at actual operating points
3-level terminal modulation / multilevel stageController supports a lower-ripple switching schemeVoltage steps and effective ripple frequency depend on implementationFirmware and sensing; a physical multilevel inverter may add switches/capacitorsDocumented terminal waveforms and current behavior across duty cycle
Custom higher-inductance windingMotor supplier can change winding while meeting speed and torque needsMore turns usually change resistance and speed constant; this is not a free increase in inductanceSample lot, winding tooling/NRE, MOQ and lead timeRevised speed-torque curve, effective L/R and temperature tests
Linear current amplifierLow switching noise is a priority and dissipation is manageableAvoids PWM carrier ripple, but amplifier heat can dominate; motor losses remainPower devices, heatsink, supply headroom and enclosure coolingDriver dissipation over speed/load, stability and motor temperature

Worked Quantitative Matrix: Six Hypothetical Electrical Cases

The following inputs are illustrative electrical cases, not catalogue frame specifications. Reproduce each result with the exact RL equations above using SI units. Assumptions: 0/V_bus terminal switching, 50% duty, bidirectional continuous current, no chokes, R_loop = R_motor, constant back EMF within a cycle, and the same assumed effective inductance at both frequencies. Values are rounded.

CaseBus (V)Effective L (µH)R (ohms)20 kHz Ripple (A pp)20 kHz Ripple Copper Loss (W)100 kHz Ripple (A pp)100 kHz Ripple Copper Loss (W)
A3.7188.50.4350.3340.3600.120
B6.0246.20.9651.0030.5510.173
C12.0324.82.3853.6840.8960.333
D24.0453.65.0779.5361.3160.525
E24.0652.14.3803.5000.9210.149
F48.01101.85.3804.3891.0900.178

Case A illustrates why multiplying frequency by five does not always divide ripple by five: the low-frequency current is resistance-limited, outside the triangular approximation. None of these rows establishes safe continuous operation; add average-current losses and compare with the actual motor's thermal rating and installation.

How to Size Series Motor Chokes for an RFQ

Step 1: Agree the Ripple Target and Required Loop Inductance

Set the target with the motor and controller suppliers using the load profile, RMS heating, current limits, brush restrictions and acoustic requirements. There is no universal 10–20% ripple approval threshold. A buyer may choose 15% as a project target, but it must be labeled as such.

Under the applicable small-ripple 0/V_bus model at 50% duty:

L_required ≈ V_bus / (4 * f_pwm * Delta_I_target)
L_external_loop = max(0, L_required - L_motor_effective - L_internal_loop)

For the worked example, an optional target of 0.15 * 0.8 A = 0.12 A at 100 kHz gives L_required ≈ 500 µH. With 30 µH effective motor inductance and no internal chokes, this means approximately 470 µH external loop inductance, or 235 µH each if split equally across two leads. Check tolerances and controller compatibility before selecting a part; the two 40 µH chokes in Case B do not meet that target.

FAULHABER AN178, pages 4–5, gives a different, application-specific rule: additional inductance of one to two times motor inductance at about 100 kHz, twice nominal supply voltage and continuous operation in its identified critical duty range. Its DC and BLDC connection arrangements differ. Do not turn that rule into a universal per-phase value or apply it to an unrelated controller without review.

Step 2: Check Peak Current and Saturation

Specify inductance retention at the maximum actual instantaneous current, including acceleration, reversal, current-limit overshoot and ripple. In the triangular model, begin with I_peak ≈ abs(I_avg) + Delta_I_pp / 2, then include the measured transient envelope. Use the inductor vendor's definition of saturation, hot bias curves and tolerances. A universal 1.5 * stall current multiplier cannot replace this check; the drive may actively limit stall current.

Step 3: Budget Resistance, Core Loss and Control Dynamics

For each choke, calculate copper loss from I_rms² * DCR_hot and obtain core-loss estimates for the actual frequency and ripple. Include voltage drop and reduced voltage headroom at high speed. Agree acceptable resistance with the system designer rather than imposing a universal percentage. Confirm that the controller supports the added inductance and retune its current loop if required.

Before requesting filter samples, attach these calculations and the waveform definition to your motor-drive compatibility enquiry.

When GaN Drivers Are Worth Evaluating

GaN can support higher switching frequency with manageable switching loss. It is a candidate when a silicon design's loss, cooling or board-space budget prevents the required PWM frequency. Silicon stages can also operate at high frequency when designed appropriately; no universal 50 kHz failure boundary applies.

TI's TIDA-00909 reference design is a documented three-phase example with 12–60 V input, 7 A RMS / 10 A peak output and testing up to 100 kHz. TI reports peak inverter efficiency up to 98.5% at 100 kHz. This is reference-board performance at specified conditions, not efficiency promised for a miniature motor or every load point.

Choose a brushed H-bridge or brushless three-phase inverter to match the motor; the cited three-phase design is not a drop-in brushed controller. Compare the complete design's current-sense settling, ADC timing, dead time, switching overshoot and EMI. A higher carrier frequency does not imply that the closed-loop current bandwidth equals the carrier frequency. Chokes may still be needed if measured ripple or thermal losses exceed the agreed limits.

Practical Procurement Checklist for RFQ Preparation

1. Drive Interface Alignment

  • State brushed versus brushless motor, controller model and exact modulation/freewheel scheme.
  • Supply nominal/maximum bus voltage, regeneration limit, PWM frequency definition and operating duty range.
  • List average, RMS and peak current limits across speed, load, acceleration and stall/reversal conditions.
  • Agree permissible ripple, winding temperature and case-temperature measurement method; distinguish project targets from supplier ratings.

2. Motor Specification and Sample Acceptance

  • Request winding resistance, terminal/phase inductance convention, measurement frequency and effective inductance under the intended PWM conditions.
  • For a custom winding, request revised speed-torque data, sample lead time, MOQ and NRE before approval.
  • Obtain brush-system drive restrictions or brushless commutation requirements from the motor supplier.
  • Require matched DC/PWM tests at no load and representative load, recording ambient, mounting, duration, temperature and current traces.

3. Electronics and Supplier Responsibility

  • For chokes, document total loop inductance, inductance under bias, saturation definition, hot DCR, RMS rating and core-loss budget.
  • Confirm controller stability, high-speed voltage headroom and protection behavior with the selected filter.
  • Verify synchronized current sampling and switching-noise rejection at the chosen PWM frequency.
  • Assign motor, driver and filter acceptance responsibilities in writing; retain sample identifiers and jointly approved test records.

Frequently Asked Questions

Why does an unloaded coreless motor get hotter on PWM than on a DC bench supply?

PWM ripple can increase RMS current and copper loss even when average torque current is small. Match speed, mounting, load and ambient before comparing supplies. Investigate commutation and control faults as well; low inductance alone does not prove the cause or predict a particular temperature rise.

Can a capacitor across the motor replace a series choke?

A capacitor directly across a switching output can create charging-current spikes proportional to C * dv/dt. It is not an interchangeable replacement for series inductance. Small manufacturer-specified brush-suppression capacitors may be appropriate; larger LC filters need compatible values, damping and control-loop review. Follow the motor and controller documentation.

There is no single minimum for every coreless motor. Determine the required frequency from modulation, bus voltage, effective inductance and permissible ripple, then verify losses and controller operation. Higher frequency is one option alongside lower bus voltage, suitable modulation and series inductance. A 100 kHz label does not establish qualification.

How should we measure current ripple during bring-up?

Measure one motor lead with a suitable current probe or a correctly designed shunt measurement. Select bandwidth and sample rate to resolve the PWM waveform, separate switching-edge artifacts from winding-current ripple, and record probe settings. Test the intended speed/load range, including the duty region with the largest ripple. Compare peak, RMS and thermal results with the agreed limits; 50% duty and a generic ripple percentage alone cannot approve the system.

Do series chokes cost less than upgrading to GaN?

Request quotations for the actual inductance, bias current, temperature, quantity and qualification grade. Compare complete channel cost including PCB area, assembly, losses, cooling, firmware and EMI validation. This guide provides no current unit-price quotations or universal cost winner.

Can the factory provide a higher-inductance winding?

Ask the supplier about feasibility. More turns can increase inductance while changing resistance, torque constant and speed constant, so the required maximum speed may become unavailable at the existing bus voltage. Require revised curves and PWM sample tests before freezing a custom winding.

Aligning Your Low-Inductance Motion Specification

Send the motor winding data, bus voltage range, controller/modulation details, load profile and target ripple with your enquiry. This gives both suppliers a concrete compatibility question to resolve.

Sources and References

Sources reviewed on 28 October 2026. Manufacturer guidance is limited to its stated motors, controllers and test conditions. The worked examples and six-case table above are reproducible calculations, not first-party hardware tests.

  1. maxon Support — PWM power stage: Current ripple & Motor chokes. Supports the distinction between PWM schemes, effective winding inductance and series-choke contribution. Its controller-specific guidance does not establish a universal 15% ripple limit.
  2. FAULHABER — Application Note 178: Reduction of PWM motor power losses using additional inductances, dated 9 April 2021. Pages 4–5 explain a conditional inductance rule; page 8 addresses controller configuration after adding inductance.
  3. Texas Instruments — TIDA-00909: 48V/10A High Frequency PWM 3-Phase GaN Inverter Reference Design for High-Speed Drives. Provides a documented high-frequency GaN example and its operating limits; it does not guarantee performance for every coreless motor.

Author