Sourcing decision baseline: Specify a miniature coreless motor holding brake against the external load, complete transmission, hot holding torque, release circuit and motion sequence. Low cogging torque does not provide dependable power-off position retention. Permanent magnet and spring-applied brakes can both hold without coil power, but their backlash, permissible release voltage and rotating inertia depend on the actual design. Obtain an approved motor–brake combination before freezing the actuator envelope.
Published and sources reviewed: 13 November 2026. Scope: Global OEM procurement and engineering screening for 10mm–24mm brushed coreless and slotless brushless DC motor frames. Motor diameter does not establish brake diameter, availability or compatibility. The maxon architecture reference covers 20mm–44mm brakes; it does not document a brake for every smaller motor frame in this guide. All unnamed numerical examples below are hypothetical design inputs, not measured performance, catalog specifications or quotations. The mechanical time-constant calculation applies to an idealized brushed DC motor. Medical-device qualification and machinery functional safety require separate application evidence.
Preparing an RFQ? Request a motor and holding-brake feasibility review with your load torque, mounting envelope, bus voltage and motion duty. For adjacent design inputs, review our bearing architecture sourcing guide, rotor inertia and acceleration guide, and low-inductance motor PWM drive guide.
Executive Summary: Key Sourcing Takeaways
- Treat power-off retention as a system requirement. Residual bearing, brush and gearbox friction may resist motion, but should not be assigned a guaranteed holding torque without qualification.
- Select the coupling as well as the brake principle. A diaphragm-coupled PM brake can avoid spline clearance. Spring-applied designs vary; neither universal backlash numbers nor a blanket temperature advantage follows from the architecture name.
- Approve voltage reduction for the exact brake. An economizer can reduce hold-open coil losses, but excessive reduction can cause dragging or re-engagement. Holding voltage here means keeping the brake released, not generating the power-off holding torque.
- Separate load-support torque from motion commands. A gravity-loaded axis needs controlled support during brake release. Delay the trajectory until release is complete; do not simply leave the drive disabled while the brake opens.
- Budget added rotating inertia. Compare total inertia and available acceleration torque, including the reflected load. A voltage-step mechanical time constant does not determine closed-loop settling bandwidth.
- Distinguish a commanded stop from total power loss. Controlled deceleration needs a functioning drive and energy path. A static holding brake alone does not establish an emergency stopping function.
1. The Physics of Backdrive: What Low Cogging Does and Does Not Mean
Cogging torque comes from position-dependent magnetic reluctance. Removing stator slotting or rotor iron from the relevant magnetic interaction can greatly reduce it. However, zero cogging does not imply zero mechanical friction or zero torque ripple under powered commutation, and cogging in an iron-core motor is not a certified holding function either.
In a brushed coreless construction, a self-supporting winding rotates around a stationary magnetic assembly. In a typical slotless BLDC motor, the winding is stationary and the permanent-magnet rotor turns. Their low-cogging behavior is useful for smooth motion, but their rotating components and control models differ.
For a backdrivable screw, use lead, the axial travel per revolution, rather than thread pitch unless the screw is single-start. Define reverse efficiency as the fraction of axial input work delivered to the rotating screw. A simple screening relationship is:
T_screw_backdrive = F_axial × lead × eta_reverse / (2 × pi)
T_motor_backdrive = T_screw_backdrive × eta_gear_reverse / iHere i = motor speed / screw speed, efficiencies refer to reverse motion, force is in newtons, lead in meters per revolution and torque in newton-meters. A self-locking transmission needs its own friction model; this equation does not prove self-locking.
Hypothetical sizing example: A 20N vertical load, 2mm lead and 0.85 reverse screw efficiency produce 20 × 0.002 × 0.85 / (2 × pi) = 5.41mNm at the screw. With a 16:1 gearbox and assumed 0.80 reverse efficiency, the motor-side load is approximately 0.270mNm. An illustrative factor of two gives a 0.541mNm screening requirement before temperature, wear, shock, uncertainty and gearbox limits are considered. For a conservative preliminary screen, use reverse efficiencies of one if friction assistance has not been qualified.
The factor of two is an example, not a prescribed safety factor. Agree acceptance criteria from the application's risk assessment, including maximum permitted displacement during engagement. Check the full load path: a rear-shaft brake cannot prevent descent after a broken downstream coupling.
Illustrative geared-motor rendering. No integrated holding brake or internal coreless winding is verified by this image; use supplier assembly drawings to establish either feature.
2. Holding Brake Topologies: Permanent Magnet vs. Spring-Applied
Both power-off architectures store the engagement force mechanically or magnetically and require electrical power to release. The supplier must specify the minimum holding torque, maximum operating speed, release voltage window, mounting orientation and environmental limits for the complete assembly.
Permanent magnet single-face brakes
A permanent magnet supplies the attraction that engages the friction surfaces. In a cancellation design, coil flux opposes that attraction and a spring lifts the armature. Other PM magnetic circuits redirect flux. Wiring polarity, voltage and temperature therefore need model-specific approval. Applying extra voltage is not a universal way to improve release.
A diaphragm coupling can transmit torque without sliding-spline clearance, but the assembly still has torsional compliance and manufacturing tolerances. Ask for angular displacement under reversing load, rather than assuming a nominal “zero-backlash” label means zero output movement. Gearbox backlash remains downstream of a motor-mounted brake.
Spring-applied friction brakes
Springs clamp a friction disc or armature; an energized coil overcomes the springs to release it. A sliding hub may introduce angular clearance, although spring-applied designs are not all mechanically identical. A bare attraction coil may be insensitive to polarity, while an integrated suppression diode, rectifier or economizer can make the wired assembly polarity-sensitive.
Compare hot torque and release behavior using the specified temperature range. Magnet grade alone cannot establish PM brake temperature capability, and the absence of magnets cannot establish spring-brake temperature capability. Friction materials, coil insulation, clearances, adhesives and seals all matter. Neither construction proves cleanroom, vacuum or medical suitability without contamination and process evidence.
The maxon brake architecture note provides named PM design examples. Its comparison is useful context, rather than a specification for every 10mm–24mm actuator.
3. Engineering Schematic: Mechanical Architecture and Control Sequencing
Figure 1: Conceptual brushed-coreless motor and PM brake, not a manufacturing drawing. The 24V-to-14.4V example represents an approved 60% hold-open voltage with approximately continuous coil current. Support torque is established before release; motion waits until release is complete. No timing scale or guaranteed thermal result is implied.
Use this diagram to review ownership of each interface. The motor supplier owns the shaft and bearing limits; the brake supplier owns engagement and release ratings; the drive integrator owns current limiting and sequencing; the machine designer owns load retention and fault behavior. Resolve inconsistent interface specifications before ordering samples.
4. Holding Voltage Reduction: Coil Losses and Approval Boundaries
A power-off brake consumes no release-coil power while engaged. During motion, its coil normally remains energized to keep it open. Calculate nominal DC losses from the actual coil resistance and reference temperature:
I_nom = V_nom / R_coil
P_nom = V_nom² / R_coilFor a hypothetical 24V, 240-ohm coil, current is 0.10A and nominal loss is 2.40W. That loss enters the actuator's thermal budget alongside motor copper losses and transmission losses. Temperature rise cannot be inferred from watts alone: mounting conduction, enclosure, ambient temperature and duty cycle are required. A first-order steady-state screen is delta_T = P_loss × thermal_resistance, using a measured or justified thermal resistance.
Why a universal 40% setting is unsuitable
For several named AB models, maxon recommends at least 60% of nominal voltage and application testing; AB20 has additional restrictions. These limits cannot be generalized to other brakes. Obtain the permitted hold-open current or voltage across hot and cold operation, vibration, acceleration and wear. Start from the supplier's release conditions, not an arbitrary low duty cycle.
Applying full nominal voltage is a release pulse; overexcitation means exceeding nominal excitation and requires explicit approval. A PM brake can have an upper release-current limit, making an unapproved boost counterproductive. Do not apply a spring-brake economizer profile to a PM brake without checking its magnetic circuit.
PWM arithmetic depends on the current waveform
With high-frequency chopping, a suitable recirculation path and approximately continuous current, the simplified relationships are:
D ≈ V_hold / V_bus
I_average ≈ D × V_bus / R_coil
P_copper = I_rms² × R_coil
P_copper ≈ D² × P_nom only when ripple is smallFor the hypothetical coil at an assumed approved 14.4V equivalent hold-open voltage, D = 0.60 and P_copper ≈ 0.36 × 2.40 = 0.864W: a calculated 64% reduction in coil copper loss. This does not establish a temperature reduction. If current becomes discontinuous, or a high-voltage clamp dissipates energy during each PWM cycle, measure RMS current and include driver losses rather than relying on D².
Choose switching frequency from coil inductance, driver limits, ripple, acoustics and EMC requirements. An inaudible frequency alone does not establish compatibility. As the maxon power-consumption note explains, standard EPOS4 and ESCON outputs normally switch fixed brake voltage; automatic brake sequencing does not imply a programmable PWM economizer.
5. Release Delay and Load Transfer: Support First, Then Move
Define t_open from the release command to the specified free-running condition. Define t_close from removal of release power to attainment of the required holding torque. Electrical current decay, initial contact and full holding torque are different events. Obtain worst-case timings with the actual cable, voltage, suppression circuit, temperature and orientation.
The EPOS4 sequencing explanation states that its power stage and control become active when release is commanded. It also explains why some load movement can occur while feedback reacts, and why load-dependent torque offset needs care. A release delay should prevent premature trajectory motion while maintaining controlled load support.
Commanded start of a gravity-loaded axis:
1. Confirm position feedback, drive readiness and a supported load.
2. Establish current-limited load-support control using the drive's approved procedure.
3. Energize the brake with the approved release voltage/current profile.
4. Inhibit trajectory motion for validated t_open(max) plus the agreed margin.
5. Verify release where feedback exists; apply approved hold-open reduction if allowed.
6. Begin motion; monitor current, position error and release faults.
Commanded stop:
1. Decelerate using the functioning drive and a suitable energy dissipation path.
2. Maintain controlled standstill and load-support torque.
3. Remove brake release power.
4. Maintain support through validated t_close(max) plus the agreed margin.
5. Confirm holding where required, then disable the power stage as specified.A timer provides an interlock, not proof that a brake opened or can hold the load. Define the reaction to failed release, excess movement, encoder loss and drive faults. Supporting torque while stationary is different from commanding a trajectory against a locked brake; current and duration still need limits to protect the motor.
For total power loss, electronic deceleration may be unavailable. Specify the permitted drop, load energy, emergency engagement speed and independent retention provisions from the application risk assessment. Do not present a software delay as a complete power-loss protection strategy.
6. Rotor Inertia Penalty and Mechanical Time Constant
Only rotating brake components add shaft inertia. Obtain armature, hub and friction-disc inertia from drawings or supplier data; the stationary coil housing does not contribute. Express all terms on the same shaft:
J_total = J_motor + J_brake + J_transmission_input + J_load_reflected
J_load_reflected = J_output_load / i² for an ideal rigid speed reduction
alpha = T_acceleration / J_totalT_acceleration is the torque remaining after load and loss torque at the actual speed. For an idealized brushed motor with negligible inductance and friction, the voltage-step mechanical time constant is tau_m = J × R_winding / (k_t × k_e) in consistent SI units. A current-controlled servo, compliant transmission or slotless BLDC drive needs a more complete model.
Hypothetical sensitivity example: Let motor inertia be 0.85g·cm², added brake inertia 1.45g·cm², winding resistance 4.2 ohms, k_t = 0.0125Nm/A, and k_e = 0.0125V·s/rad (approximately 1.31mV/rpm). Using 1g·cm² = 10^-7kg·m², the simplified no-load time constant increases from 2.28ms to 6.18ms. With constant available acceleration torque of 25mNm, acceleration falls from approximately 294,118 to 108,696rad/s², a 63% decrease.
If the same shaft already carries 10g·cm² of reflected load inertia, adding this brake increases total inertia by only 1.45 / (0.85 + 10) = 13.4%. This distinction prevents an exaggerated conclusion from the brake-to-rotor ratio alone. Check settling, regenerative energy and motor temperature against the complete trajectory. A higher supply voltage does not automatically authorize higher current or restore acceleration.
7. Architectural Sourcing Matrix: Six Backdrive Prevention Options
The matrix compares mechanisms rather than catalog ratings. Clearance, life and thermal performance require evidence for the selected assembly.
| Architecture | Power-off retention | Angular behavior | Electrical and thermal burden | Inertia or packaging effect | Qualification priority |
|---|---|---|---|---|---|
| Permanent magnet holding brake | Magnetic attraction engages friction surfaces | Diaphragm designs can avoid spline clearance; verify torsional deflection | Release-coil losses during motion; model-specific reduction limits | Rotating armature and hub add inertia | Polarity, upper/lower release limits, hot holding torque |
| Spring-applied holding brake | Springs engage friction surfaces | Sliding hub may introduce clearance; coupling dependent | Release-coil losses; economizer must be approved | Disc and hub add inertia | Clearance, lining wear, spring integrity, release margin |
| Self-locking worm transmission | Conditional on geometry, friction and operating state | Gear clearance and elastic deflection remain | No holding-coil power; sliding losses during motion | Check actual input-side inertia | Reverse-load tests under vibration, lubrication and wear |
| High-ratio planetary transmission | Ratio alone does not guarantee locking | Backlash accumulates through the gear train | No brake-coil power; friction changes with temperature | Reflect output load by ratio squared | Minimum reverse breakaway torque throughout life |
| Motor-terminal dynamic short circuit | No static lock at zero speed | Opposes movement as back-EMF develops | Winding and switching losses during deceleration | No added mechanical brake rotor | Power-loss switching state, current and permitted descent |
| Mechanical pin or latch | Retains only after confirmed mechanical engagement | Discrete positions or latch clearance | Actuation may be pulsed or continuous, depending on design | Latch ring, linkage and installation space | Alignment, shear capacity, engagement confirmation and shock |
A self-locking claim needs final-assembly validation. A gear ratio or lead-angle threshold alone cannot guarantee retention under vibration. Likewise, a motor-side brake leaves downstream gear clearance available for output movement. Specify the actual output displacement limit under a reversing external torque.
8. Six Hypothetical Motor–Brake Screening Scenarios
The following rows are invented sensitivity inputs, not available products, matched brake models or supplier performance data. Diameter denotes the motor frame only; the brake may require a larger envelope. Holding torque and release time must remain supplier-confirmed fields, so no unsupported ratings are assigned here.
Nominal power uses the assumed resistance shown in each row. Reduced power assumes supplier approval for 60% hold-open voltage, unchanged resistance and negligible current ripple. The unloaded inertia multiplier is (J_motor + J_brake) / J_motor, excluding transmission and load inertia.
| Motor frame input | Coil voltage (V) | Assumed coil resistance (ohms) | Motor inertia (g·cm²) | Added brake inertia (g·cm²) | Added inertia (%) | Nominal coil loss (W) | 60% voltage coil loss (W) | Unloaded inertia multiplier |
|---|---|---|---|---|---|---|---|---|
| 10mm example | 12 | 130 | 0.22 | 0.35 | 159 | 1.108 | 0.399 | 2.59 |
| 12mm example | 12 | 100 | 0.55 | 0.85 | 155 | 1.440 | 0.518 | 2.55 |
| 16mm example | 24 | 275 | 0.85 | 1.45 | 171 | 2.095 | 0.754 | 2.71 |
| 17mm example | 24 | 240 | 1.10 | 1.80 | 164 | 2.400 | 0.864 | 2.64 |
| 22mm example | 24 | 205 | 3.20 | 3.80 | 119 | 2.810 | 1.012 | 2.19 |
| 24mm example | 24 | 170 | 5.40 | 5.20 | 96 | 3.388 | 1.220 | 1.96 |
These calculations identify questions to resolve, rather than approving a design. The smaller-frame assumptions produce large brake-to-rotor ratios; a load-dominated actuator may see a much smaller percentage change. Every row still has coil heat after reduction. None predicts casing temperature, permissible acceleration or dynamic stopping life.
For ideal static gearing, a 20mNm motor-side brake and 64:1 ratio give a 1.28Nm torque relationship at the output. This is not an approved output holding rating. Check the gearbox static torque limit, shafts, fasteners, backlash, reverse behavior and required margin. Do not apply an undefined “static efficiency” to manufacture a guaranteed payload capacity.
Send your load and inertia budget for an integration review when any assumed parameter controls acceptance. Request a named brake, dimensional drawing and qualification plan before comparing prices.
9. Failure Modes and Qualification Risks
Dynamic engagement and friction damage
A static holding rating does not specify stopping energy. Calculate rotational kinetic energy with E = 0.5 × J_total × omega² using rad/s, then include any potential energy released by a descending load. If emergency dynamic engagement is required, obtain explicit limits for speed, energy per stop, cumulative work and post-stop holding torque. No universal number of emergency stops or allowable engagement RPM can be inferred from frame diameter.
Axial loads and bearing interfaces
Review how attraction and spring forces close through the brake housing, armature coupling and shaft. Request permissible motor axial load, assembly preload and axial float for the actual bearing arrangement. An unsuitable installation can overload bearings or cause drag; generic miniature-bearing force ranges cannot approve it. Include the mounting process and press-fit support fixture in the interface review.
Hot release and magnet behavior
For copper, a screening relation near ordinary operating temperatures is R(T) ≈ R(20°C) × [1 + 0.00393 × (T - 20°C)]. Rising resistance changes coil current at fixed voltage. Verify release at the hot minimum supply and the cold maximum supply. For PM brakes, irreversible demagnetization can occur below the Curie temperature depending on grade, magnetic circuit and opposing field. Obtain the brake's approved temperature limits and measured hot torque rather than mandating a magnet chemistry from ambient temperature alone.
Suppression circuit and engagement lag
A simple freewheel diode generally slows current decay compared with a higher-voltage clamp. The important variable is recirculation voltage, not whether the diode is called “fast.” Size any TVS or diode–Zener network against coil energy 0.5 × L × I², repetition rate, insulation and the driver's actual switch voltage stress. A nominal 24V bus does not establish a safe clamp voltage. Measure engagement with the final circuit; do not substitute a generic millisecond claim.
10. Practical Procurement Checklist for RFQ Preparation
Use this checklist to make supplier quotations comparable and define unresolved requirements before sample approval.
Mechanical and load specification
- State axis orientation, maximum external load, screw lead, gear ratio and reverse-efficiency assumptions.
- Specify minimum hot and worn holding torque, required margin, maximum output displacement and acceptance method.
- Obtain motor and brake envelopes separately, including encoder stack, cables, shaft interfaces and assembly tolerances.
- Record total rotating inertia and required torque at speed; include transmission and reflected load.
- Declare static holding duty and any emergency dynamic engagement speed, energy and lifetime count separately.
Electrical, thermal and sequencing definition
- Agree minimum and maximum release voltage/current over temperature, cable drop and bus tolerance.
- Obtain written approval for any overexcitation or hold-open reduction, including PWM waveform and recirculation circuit.
- Identify whether the controller supplies only an on/off signal or includes an actual power-rated brake driver.
- Define support torque, trajectory inhibit, worst-case opening/closing delays and fault reactions.
- Include nominal and reduced coil loss in the final enclosure thermal test; specify motor winding and bearing temperature limits.
- Agree polarity marking, connector keying and suppression placement, including any internally fitted electronics.
Acceptance evidence and change control
- Test cold and hot holding torque and timing using the final drive, wiring and mounting arrangement.
- Record coil voltage/current, encoder position and relevant brake-state signals on a common time base.
- Distinguish current decay from attainment of holding torque; define test torque, allowed movement, sample size and uncertainty.
- Check power-loss displacement, wear, vibration and contamination limits under representative loads.
- Require traceable drawings and notification of friction material, magnet, spring, firmware or suppression changes.
A supplier's test plan should state fixture orientation, torque ramp rate, dwell, temperatures and pass/fail limits. An encoder detects movement; it does not independently measure holding torque. Use a controlled applied load or calibrated torque measurement for that acceptance test. Cleanroom particle and outgassing requirements need defined limits and methods, rather than a promise of “no contamination.”
11. Frequently Asked Questions
Can a holding brake perform routine deceleration?
Use a static-only brake for standstill holding. Some brakes have explicit emergency stopping ratings, but these do not imply unlimited routine friction braking. For commanded stops, decelerate through the motor drive before engagement. For total power loss, qualify the separate emergency load-retention behavior and energy limits.
What PWM duty cycle should we specify?
Specify the brake's approved hold-open current or voltage first. With a suitable driver and continuous coil current, duty is approximately approved average voltage divided by bus voltage. For example, 14.4V from 24V gives 60%. Validate RMS current, vibration and temperature behavior. Neither 40% duty nor a frequency above 20kHz is a universal approval criterion.
Should motor torque begin only after the brake opens?
Trajectory motion should wait for confirmed or validated release. Load-support torque may need to exist before and during release on a gravity-loaded axis. Use current limits and the drive's commissioning procedure; otherwise the load can move before position control reacts. A brake delay and a motor-enable delay are different settings.
Does PM mean zero backlash and spring-applied mean loose positioning?
No universal rule follows. Compare the actual coupling, specified angular clearance and stiffness. A PM diaphragm design may avoid spline backlash, while complete-axis motion still includes shaft and transmission compliance. Measure output displacement at the required reversing torque and temperature.
Can a high-ratio planetary gearbox replace the brake?
Only if the complete transmission has an explicitly qualified retention capability for the required load, environment, wear and fault conditions. Ratio alone does not provide that capability. Motor-terminal shorting can slow motion but supplies no back-EMF braking torque at zero speed, so it does not create a static mechanical lock.
How do we qualify a 10mm motor with an integrated brake?
Request a specific motor–brake assembly drawing, part identification and supplier ratings. A 10mm motor does not imply a 10mm brake, and larger-brake architecture notes do not establish smaller-product availability. Leave space and timing assumptions open until the supplier confirms the combination and the sample test plan.
12. Aligning Your Motor and Holding Brake Specification
Treat the motor, brake, encoder, transmission and driver as one qualification package. Separate supplier-confirmed ratings from arithmetic assumptions in the RFQ so a provisional calculation cannot become a production promise.
Use the bearing architecture sourcing guide for the shaft load interface, the coreless motor dynamic balancing guide for rotating assembly requirements, and the low-inductance PWM drive guide for the motor power stage. The motor winding PWM and the brake-coil economizer are separate circuits with separate approval requirements.
Contact our precision motion team with the axis orientation, peak backdrive load, required holding displacement, available bus voltage, mounting envelope and operating temperatures. Ask which combinations and documentation can be supplied, then agree sample acceptance criteria before production tooling. Availability, CAD delivery and qualification scope should be confirmed for the quoted assembly.
13. Sources and References
- maxon — Brake: What to consider. Manufacturer note covering named 20mm–44mm AB brakes, PM magnetic circuits, voltage-reduction limits and assembly considerations. Its scope does not establish 10mm–24mm brake availability.
- maxon — EPOS4's automatic “Holding brake” control: A detailed look. Drive sequencing explanation, including active control during release, possible vertical-axis movement and load-dependent torque offset considerations.
- maxon — What is the power consumption of a brake?. Coil current and power calculation, model-specific voltage reduction and fixed-voltage controller output limitations.
Evidence boundary: These three accessible manufacturer URLs support specific architecture, sequencing and coil-power statements. They are one manufacturer's documentation, not three independent test programs. Unnamed dimensions, loads, resistances and inertias are declared hypothetical inputs. The calculations are reproducible screening aids; no first-party hardware tests, certified safety function, customer outcome or warranty is claimed. Review again when the quoted brake, drive circuit, load or duty changes.
Author
Categories
More Posts

Coreless Motor Sourcing 2026: Navigating the Post-EUA Medical Compliance Shift and Section 301 Tariffs
Coreless motor sourcing briefing for the June 30, 2026 EUA scenario and Section 301 tariff actions. Use Q3 supplier audit steps and RFQ checkpoints now.
Miniature Coreless DC Motor Rotor Dynamic Balancing and High-Speed Vibration Control (10,000–60,000 RPM): ISO 21940 Balancing Grades, Residual Unbalance (U_per), Acoustic Noise, and Bearing Life Sourcing Guide (2026)
Compare coreless motor dynamic balancing grades, calculate residual unbalance, and use the RFQ checklist to define vibration, noise, and supplier acceptance.

Beyond Unit Price: The 2026 Coreless DC Motor TCO Framework for Procurement
Use this coreless DC motor TCO framework to compare suppliers, quantify hidden assembly, battery, MOQ, and warranty costs, and prepare a stronger RFQ.